Netshield SA moves beyond conventional surge protection

29 October 2008 Circuit & System Protection

Electronic research and development house, Netshield SA, has released a new third-generation managed and isolated surge protection system (SPS) that replaces mechanical circuit breakers and incorporates power condition monitoring and SNMP management.

The new SPS addresses shortcomings in conventional surge protection methodologies which, according to Netshield MD Inus Dreckmeyr, often provide users with a false sense of security.

“Many organisations found this out the hard way with the recent spate of load shedding which sometimes resulted in power literally surging back,” he says. “Another problem occurs when electricity in a building trips as a result of a power surge and someone simply flips the trip switch to restore power. While it may appear that everything is back to normal, the power protection unit could have failed, and the next surge that comes along could pass right through the ‘clamp’ and destroy vital equipment.”

In addition, lightning strikes can be just as devastating as induced surging from switching loads on the power grids. These can be carried into the building via electrical wiring, telecommunications lines and antennas. Where surge protection is applied, it usually involves placing a protection device on a line. The device will simply clamp the line to prevent the surge from passing through to the equipment being protected.

This works well – once and possibly twice. Most of these units are designed to absorb only a certain amount of energy. Once that level is reached, the unit fails. The problem is that it is often not known when or if a unit has failed until equipment is damaged.

Netshield, therefore, takes a different approach to surge protection. “What many regard as the most important defence against surges is just a first line of defence for us. We apply a second defence and not a single failure jump has been reported in more than a decade,” Dreckmeyr says.

The new Netshield SPS incorporates a 2U mountable unit that is AC powered and is designed to protect the user’s mains from the lightning and surges which would typically occur on the input 220 V on a 19” cabinet. Optional data protection modules for external telecoms data lines like x.21, Ethernet, ADSL and E1 are also available.

The SPS has a manageable port though which the user can configure and read a variety of settings via the SNMPV1 protocol. Limits like voltage upper and lower limits can be set up. When the unit’s parameters are outside limits, the unit will automatically send SNMP traps to a designated IP address to indicate alarm conditions.

The user can also switch the mains on or off, set the site name, time, date or check the serial number and version of the unit via SNMP.

At the back of the SPS is a RS485 bus to which the user can connect up to two high power probes.

The Netshield high power probe with its high surge handling capability, over-current fusing and a resettable current trip setting, provides a mains surge protecting solution for users in telecoms, commercial and industrial environments. The probe has a manageable interface and it can be configured and managed either remotely or on-site via the Netshield Sensor Protocol.

An onboard tactile switch allows the user to switch the mains on or off and clear the accumulated power usage (kWh).

Another optional enhancement for the SPS is an automatic power failover switch (APFS) which provides a solution during power outages when power needs to be fed automatically from a secondary source like generators or solar panels. The APFS can work as a standalone unit or in conjunction with the Netshield SPS. In standalone configuration, the unit will sense the normal mains and switch over to the secondary source when a failure occurs or when the primary source is not stable.

Using the Netshield Sensor Protocol the user can configure or read remotely the APFS settings such as manual switch over, or statuses such as generator diesel level. If configured for generator mode, the AFPS unit is able to sense the diesel level of the generator, determine how long the generator has been running and see when last it was serviced. The user is also able to manually switch the generator on and off, and switch over to the primary or secondary input power source.

When configured for solar panel mode, the unit can sense the battery pack power level and determine whether or not it is safe to switch over to the solar panel.

For more information contact Inus Dreckmeyr, Netshield SA, +27 (0)12 424 9345.





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Clearing the Static: Understanding the significance of ESD audits
Actum Electronics Circuit & System Protection
An ESD (Electrostatic Discharge) audit is the first step in establishing an ESD plan, and it is important to include all areas where ESD-sensitive components are being handled.

Read more...
Microchip introduces ECC608 TrustMANAGER
Altron Arrow Circuit & System Protection
To increase security on IoT products and facilitate easier setup and management, Microchip Technology has added the ECC608 TrustMANAGER with Kudelski IoT keySTREAM, Software as a Service (SaaS) to its Trust Platform portfolio of devices, services and tools.

Read more...
Varistors for automotive applications
Future Electronics Circuit & System Protection
TDK Corporation has announced the addition of two new varistors to its AVRH series for automotive applications where both are characterised by the high electrostatic discharge-withstanding voltage demanded to ensure the safe operation of safety-critical automotive functions.

Read more...
Clearing the Static: The importance of ESD wrist straps
Actum Electronics Circuit & System Protection
ESD clothing plays a pivotal role in preventing that people do not charge the products that they are working with.

Read more...
Clearing the Static: ESD clothing and footwear
Actum Electronics Circuit & System Protection
ESD clothing plays a pivotal role in preventing that people do not charge the products that they are working with.

Read more...
Single-phase EMC filters
RS South Africa Circuit & System Protection
TDK Corporation has expanded its portfolio of single-phase EMC filters for AC and DC applications up to 250 V and rated currents from 6 to 30 A.

Read more...
Clearing the Static: The significance of cleaning in ESD control
Actum Group Circuit & System Protection
It is essential that ESD-protected workplace areas and equipment (tables, floors, work mats, trays, tools, machine elements) are cleaned with specialised antistatic cleaners.

Read more...
Clearing the Static: ESD protective packaging
Actum Group Circuit & System Protection
The primary objective of ESD protective packaging is to prevent ESD incidents within the packaging and facilitate the dissipation of charges from the outer surface.

Read more...
New NeoMesh protocol stack version
CST Electronics Circuit & System Protection
NeoCortec has released an updated NeoMesh protocol stack version 1.6 firmware for its NC2400 and NC1000 module series, which now supports the new Sensirion SHT4xA temperature and humidity sensor series.

Read more...
NewFeed feeder protection relay
NewElec Pretoria Circuit & System Protection
The NewFeed Feeder Protection Relay has been designed to protect the connection between solar farms and conventional power grids in both low voltage (LV) and medium voltage (MV) distribution settings.

Read more...