Circuit & System Protection


Clearing the Static: Conductive foot, heel and shoe grounders

28 March 2025 Circuit & System Protection


Greg Barron, Actum Group director

Conductive foot, heel and shoe grounders are used in electrostatic discharge protected areas to provide a path to ground for static electricity. This assists in preventing a build-up of static electricity, which can cause damage to sensitive electronic components.

The range of grounders are designed to be worn on the heel of the shoe, and they provide a direct connection to the ground through conductive floors or mats, allowing static electricity to be safely discharged. They are a safe alternative to ESD shoes. ESD foot grounders are easy to install and can be used on standard shoes by placing the grounding tab in the shoe under the foot.

Actum offers a range of basic heel grounders, reversible heel grounders and shoe grounders. Reversible options are longer lasting as once the one side is worn, you can just rotate them to use the other side. Shoe grounders must be worn on both shoes to maintain the integrity of the body-to-ground connection, even when one foot is lifted off the floor.

Any shoe grounder should not be worn in isolation, but forms part of a complete grounding system, which consists of a wrist band, cord and conductive flooring. Disposable shoe covers are also available and should be worn with a grounding tab for permanent grounding.

Features of Actum shoe grounders:

• Quick-release buckle.

• Unique elasticised rear section provides comfort for all shoe types.

• Brightly coloured heel band for clear identification.

• Reinforced black conductive rubber.

• Easy to fit and adjust to any shoe size.

• Leaves no scuff marks.


Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Electrical fire safety in lithium-ion battery rooms
Circuit & System Protection
Pratliperl is a non-combustible, ultra-lightweight aggregate that can be mixed with cement and applied as a plaster or screed to walls, floors, and ceilings.

Read more...
Clearing the Static: ESD training in the workplace
Actum Circuit & System Protection
To protect sensitive electronic components, A structured, consistent, and sustainable ESD training program is essential.

Read more...
Protect your pumps – protect your profit
NewElec Pretoria Circuit & System Protection
In South Africa’s demanding agricultural landscape, irrigation is not just an essential service – it is the heartbeat of farm productivity.

Read more...
Clearing the Static: ESD and installation: A durable antistatic solution
Actum Circuit & System Protection
ESD flooring provides a reliable, long-term solution for managing static electricity by safely dissipating static charges through the floor to a designated ground point.

Read more...
Why wait to automate
NewElec Pretoria Circuit & System Protection
NewElec’s initiative helps you gain operational visibility via HMI or PLC by retrofitting intelligent motor protection relays without replacing MCCs or rewiring the plant.

Read more...
Clearing the Static: Effectively control static in your workplace
Actum Circuit & System Protection
Controlling electrostatic discharge in the workplace is crucial to protect sensitive electronic equipment from damage. Implementing an ESD control program involves various measures and tests.

Read more...
Clearing the Static: Staying grounded: Ensuring effective ESD control
Actum Circuit & System Protection
To maintain reliable electrostatic discharge control, regular testing and accurate measurement are essential, with grounding products and ESD testing equipment being vital.

Read more...
Clearing the Static: ESD component safety in storage and transportation
Actum Circuit & System Protection
Conductive containers create a Faraday cage effect, safely channelling electrostatic charges away from the components inside.

Read more...
Film and mica capacitors
Actum Passive Components
By utilising various polymer dielectrics plastics, Exxelia film and mica capacitors meet most technical requirements and serve all functions from standard filtering to specialised applications.

Read more...
LED driver for industrial power supply indication
Altron Arrow Editor's Choice Circuit & System Protection
A simple and small solution for driving an LED to provide visual feedback in the presence/absence of a system’s power using a chip not originally designed for this purpose.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved