Several years ago DIN 41612 plating specifications were changed from four performance levels (classes) to the now currently used three performance levels. Certain manufacturers immediately provided a new 4th class - the 200 mating class version (although DIN 41612 does not specify a performance level with 200 mating cycles).
Erni decided against the 200 mating cycle version because they would not be much more price competitive than with the 400 mating cycle version as many more piece parts have to be handled, plus about 25% more connector part numbers would have to be provided.
The test procedure differs and is as follows: After 200 mating cycles the corrosion test is carried out whereafter another 200 mating cycles are made. Then connectors which have now made 400 mating cycles are put through the final test procedure.
Erni strongly recommends that a minimum of Class 2 connectors (400 mating cycles) are used for all severe environmental applications, eg in industry, salt air/atmosphere, etc. In these environments it is not only the number of insertions that is important but the connector's ability to withstand corrosion and continue to function in harsh environments that is vital.
This applies particularly in industries such as: mining - both on surface and underground; chemical - paper mills oil refineries and synthetic fuel plants; marine electronics; iron steel and ferrous metal plants; detergent and soap factories.
mBend cable assemblies Conical Technologies
Interconnection
The mBend cable assemblies from Anoison are designed to meet the growing demand for low-profile coaxial connections in applications where space is limited, and precise bending is necessary right next to the connectors.
Read more...Configurable DIN rail housings Wiltron Agencies
Interconnection
With PTR HARTMANN’s INS265 design kit, DIN rail housings can be individually configured using a wide range of options.
Read more...Clearing the Static: Cleaning in an ESD-protected area Actum Electronics
Circuit & System Protection
Cleaning in a protected electrostatic discharge area is a critical task to maintain the integrity of sensitive electronic components and prevent damage caused by static electricity.
Read more...ESD vinyl flooring Actum Electronics
Manufacturing / Production Technology, Hardware & Services
ESD vinyl needs to be earthed by laying a conductive carbon or copper-based adhesive to glue down the sheeting.
Read more...ESD chair Actum Electronics
Manufacturing / Production Technology, Hardware & Services
An ESD chair forms an integral part of grounding within the ESD protected area to prevent damage to sensitive components.
Read more...Connectors for the latest server applications Spectrum Concepts
Interconnection
To deliver high-speed performance, many next-generation server applications will use cables inside the box instead of PCB traces to maintain the signal integrity demanded by high-speed communications.
Read more...Industrial Ethernet with HARTING solutions
Interconnection
In today’s fast-paced industrial landscape, Ethernet connectivity plays a crucial role in automation, ensuring seamless communication between machines and systems, and HARTING offers a wide range of innovative Ethernet products.
Read more...Steel wire cable tray systems RS South Africa
Interconnection
Legrand has developed a zinc aluminium finish surface treatment for its Cablofil steel wire cable tray system to minimise the threat of zinc whiskers forming.