Analogue, Mixed Signal, LSI


What is horizontal convection reflow technology?

21 February 2007 Analogue, Mixed Signal, LSI

Leading up to the development of lead-free soldering alloys, Novastar developed ‘horizontal convection’ for the soldering reflow process. Novastar has pioneered innovations such as baffle-free solder pots, high efficiency preheaters, exchangeable heater technology, efficient low cost forced-air systems and now, its horizontal convection reflow oven technology can deal with the precise profiles required by lead-free solders.

Getting the correct temperature profile, with the narrow process window in lead-free applications is now more important than ever. In each chamber or 'zone', air is circulated toward one side of the oven above the PCB and toward the opposite side of the oven below the PCB, forming a 'cyclone' around the board (Figures 1 and 2). This forced air circulation results in a uniform temperature profile along the entire circuit board assembly. This technology is ideal for the precise profiles needed for lead-free soldering.

Figure 1. Cross-section of a 1200HC horizontal convection oven. The air is recirculated within the confines of each chamber
Figure 1. Cross-section of a 1200HC horizontal convection oven. The air is recirculated within the confines of each chamber

Figure 2. By controlling the air flow around the board by having consistent temperature, air pressure, air velocity, volume and direction across the board, temperature uniformity is ensured
Figure 2. By controlling the air flow around the board by having consistent temperature, air pressure, air velocity, volume and direction across the board, temperature uniformity is ensured

Horizontal convection defined

* The main difference between horizontal convection and traditional oven technology:

In traditional reflow ovens, air currents are introduced vertically from above and below on the PCB while in horizontal convection, air is circulated horizontally in one direction across the top of the board and in the opposite direction beneath the board. This is key. This prevents hot spots and because of this parallel 'angle of attack' the air stream's ability to infiltrate the spaces underneath component bodies such as BGAs and J-leaded devices is enhanced. Temperatures across the entire PCB front to back are thus virtually identical (Figure 3).

Figure 3. Graph shows the profile taken in a 1200HC 3-Zone oven showing actual board temperatures recorded with 6 thermocouples evenly positioned across the board
Figure 3. Graph shows the profile taken in a 1200HC 3-Zone oven showing actual board temperatures recorded with 6 thermocouples evenly positioned across the board

* Lower overall equipment cost and operation cost:

Because the horizontal convection system requires neither plenum nor air re-introduction apparatuses, it is (due to its simplicity) more reliable and less costly. There is no need for costly flux management systems as there is no sticky flux residue in the oven. This greatly reduces the need for constant cleaning, maintenance and servicing.

* Eliminates hot spots across the board:

By controlling the air flow around the board by having consistent temperature, air pressure, air velocity, volume and direction across the board, temperature uniformity is ensured. The top and bottom of the board receive the air from the outsides toward the centre, which acts to counter the centre hot-spot/cool-outside condition (Figure 3). This minimises thermal stress to PCB materials and components.

* No flux management system is needed:

There is no flux residue because the air is recirculated within the confines of each chamber. Chambers each contain all the elements needed to be self-sufficient: heating elements, fan blades, inert gas suffusers and exhaust ports. The air never comes into contact with cooler surfaces and thus does not condense anywhere within the oven.

* Uses less nitrogen in inert atmosphere applications:

An advantageous side-effect of the system is an ability to produce low oxygen ppm (parts per million) levels when purging with inert gas, because the volume of space to be affected includes only the confines of each chamber. In traditional oven design, by contrast, the chamber as well as the upper and lower plenums must be purged.

* The best profiles!

There are multiple reasons for this claim. Heated air within each zone is extremely controllable and precise. Temperatures across the board are uniform with no hot spots because air is circulated horizontally in a circular or 'cyclone' motion around the PCB. Temperatures across the entire PCB front to back are virtually identical.



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

High-reliability isolation amplifiers
EBV Electrolink Analogue, Mixed Signal, LSI
The VIA series of isolation amplifiers from Vishay are designed to deliver exceptional thermal stability and precise measurement capabilities.

Read more...
Mibbo QT2C Series signal isolators
Conical Technologies Analogue, Mixed Signal, LSI
The Mibbo QT2C Series isolators support a rich combination of input and output signals, working with either current loops or voltage levels.

Read more...
IMU with dual-sensing capability
EBV Electrolink Analogue, Mixed Signal, LSI
ST’s 6-axis inertial measurement unit integrates a dual accelerometer up to 320g and embedded AI for activity tracking and high-impact sensing.

Read more...
Plural data converter series
Analogue, Mixed Signal, LSI
Silanna Semiconductor has announced the launch of Plural, a new generation of data converters for customers eager to find a more available, affordable, high-performance alternative to existing brands.

Read more...
Precision JFET op-amp
Altron Arrow Analogue, Mixed Signal, LSI
The specifications of the ADA4620 make it optimal as a front-end amplifier in a data-acquisition system, or for a TIA circuit with high input impedance.

Read more...
A new era in modular I/O solutions
Rugged Interconnect Technologies Analogue, Mixed Signal, LSI
Aerospace and defence system designers are demanding scalable and high-performance I/O solutions and while traditional mezzanine standards have proven reliable, they often fall short of meeting modern bandwidth, size, and flexibility requirements.

Read more...
High voltage instrument op-amp
iCorp Technologies Analogue, Mixed Signal, LSI
The SGM621B is a high accuracy, high voltage instrumentation amplifier, which is designed to set any gain from 1 to 10 000 with one external resistor.

Read more...
High-speed SAR ADC simplifies design
Altron Arrow Analogue, Mixed Signal, LSI
The ADI AD4080 simplifies data converter integration by integrating a low drift reference buffer, low dropout regulators and a 16K result data FIFO buffer.

Read more...
2-wire quad voltage output DAC
Altron Arrow Analogue, Mixed Signal, LSI
The DAC has a 2-wire serial interface that operates at clock rates up to 400 kHz, and this interface is SMBus compatible, allowing multiple devices to be placed on the same bus.

Read more...
Dual-channel ADC for RF applications
RFiber Solutions Analogue, Mixed Signal, LSI
The ARF0471 from Advanced RF is a dual-channel, 14-bit, 3 GSPS ADC, which features an on-chip buffer and sample-and-hold circuit.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.