Circuit & System Protection


Mechanical design tips for EMI shielding

23 March 2005 Circuit & System Protection

Nowadays every company is involved with CE/EMI demands. The use of electronics increases as well as the frequencies.

Therefore radiation and immunity has to be taken into account in an early stage during the development of new products. In many cases EMI problems cannot be solved at PCB level; the enclosures and cables will have to be shielded.

When to use shielding?

Shielding is a fast way to comply with legal demands like CE or FCC or to prevent electro-magnetic interference. Since time-consuming development is not required, shielding is cost-effective. Therefore shielding is used for smaller production quantities or if a quick market introduction is needed. It is also used for appliances with high radiation or sensitivity levels or for products of which these levels are not known in advance, like modular enclosures.

Electro-magnetic interference can be transferred by radiation and conduction. Conduction plays an important role with frequencies below 10 MHz. To prevent this, cables and enclosures have to be shielded with magnetically conductive materials. The lower the frequency, the thicker the shielding needs to be.

For high frequencies (HF shielding, >40 MHz), only a very thin layer of highly conductive material is needed.

Avoid gaps

The higher the frequency, the shorter the wavelength. This means that when the frequency increases, the tolerable gap dimensions decrease. In other words: doors, panels and other parts need to be connected electrically on all sides. The easiest way to do this is with highly conductive EMI shielding gaskets. Most of them are self-adhesive for easy mounting.

To select the appropriate gasket, several aspects have to be taken into account: the rigidity of the construction, the distance between the fixings, the distance between them and the construction materials used.

The allowed stiffness of the gasket depends on the rigidity of the construction and the distance between the fixings. If the gasket is too stiff, the door, lid or panel will deflect and gaps will be caused instead of prevented (Figure 1). Especially for doors several kinds of gaskets have been developed, which combine a very large compression range, low closure force and high conductivity. Many of them can be used in existing products, without changing the construction.

Figure 1. Deflection of parts due to excessive stiffness of the gasket
Figure 1. Deflection of parts due to excessive stiffness of the gasket

Galvanic corrosion

The conductive layer on the outside of the gasket needs to be in the same galvanic range as the construction materials, otherwise galvanic corrosion will occur and the electrical conduction between the parts will be lost. This will decrease the shielding performance. Commonly used criteria: no more than 0,3 V for harsh environments (salt spray/weathering) and no more than 0,5 V for benign environments (indoors, salt-free condensation only).

To obtain a contact surface within the same galvanic range as the conductive covering of the gaskets, a metal tape with conductive self-adhesive can be applied. This can be provided with a masking tape of a smaller width. The paint overlaps the tape, which increases bonding and corrosion resistance (Figure 2). Another way to avoid galvanic corrosion is to take care that the environmental influences do not reach the EMI shielding gasket, for example with a combined EMI/water seal (Figure 3).

Figure 2. Metal tape with conductive self-adhesive to increase corrosion resistance
Figure 2. Metal tape with conductive self-adhesive to increase corrosion resistance

Figure 3. Combined EMI/water seal
Figure 3. Combined EMI/water seal

Some manufacturers of EMI shielding gaskets use carbon containing layers on the outside to prevent corrosion of the gasket. Please be aware that these are not galvanically compatible with many commonly-used construction materials and that corrosion of the contact surfaces of the construction will take place. EMI shielding gaskets with a conductive layer of reinforced 'Amucor' foil are much more compatible with materials like zinc plated steel and aluminium, and will prevent this kind of corrosion.

Displays/vent panels

Not only connections between construction parts, but of course also displays and vent panels need to be shielded. Displays can be provided with a sputtered transparent conductive coating for HF shielding (>30 MHz, Figure 4a) or a fine metal wire mesh for lower frequency/high performance shielding (Figure 4b). The conductive sputter layer can be coated directly on the display or can be supplied on thin films for smaller amounts. Of course, the shielding of the displays will have to be connected with the shielding of the enclosure to guarantee optimal damping. This can be done with a gasket or metal tape with conductive self-adhesive.

Figure 4a. Shielded display with conductive transparent foil, connected with metal tape
Figure 4a. Shielded display with conductive transparent foil, connected with metal tape

Figure 4b. Shielded display with laminated metal wire mesh, connected with a gasket
Figure 4b. Shielded display with laminated metal wire mesh, connected with a gasket

Vent panels are usually shielded with aluminium honeycomb vents. These give excellent shielding performance with minimal loss of airflow. For superb shielding performance so-called cross-cell honeycomb vents are used. These consist of two or more layers of aluminium honeycomb, rotated 90° (Figure 5). Honeycombs are usually applied with a rigid aluminium frame and a gasket of 2-5 mm for optimal connection with the construction.

Figure 5. Cross-cell honeycomb vent
Figure 5. Cross-cell honeycomb vent

Cables

To prevent radiation from escaping past the shielding through power and signal cables, they need to be shielded or filtered. Shielding can be provided by ready-made shielded cables, shielding tube and cable wrapping. Shielding tube consists of hollow braided metal wire, through which the cable or bundle of cables can be pulled to shield it. Cable wrapping is a knitted metal wire tape, which is wrapped around a cable or bundle of cables. With this, it is very easy to make branches.

The shielding of the cables always needs to be connected properly with the shielding of the enclosure; otherwise the cable will act as an antenna and the shielding will be useless. For heavy duty and military applications, shielded cable glands and special cable entry systems with compressed conductive rubber seals are commonly used. For commercial applications and appliances that do not need a water seal, Entry-shield is used in most cases. Entry-shield consists of two pre-compressed flexible strips of EMI shielding gasket, between which the cables are entered. This way, many cables can be entered simultaneously with minimal mounting and it is very easy to add cables later (Figure 6).

Figure 6. Entry-shield
Figure 6. Entry-shield

Connectors

What was said about cables also applies for connectors. These also need to be shielded or filtered and connected with a gasket. These gaskets can consist of 1 mm thick die-cut material, which can also be manufactured easily according to customer specifications, with little tooling costs.

Shielding at the source

If the source of the radiation or sensitivity is known, shielding can be done at the source. The interfering parts can be packed in a folded box or envelope of die-cut shielding foil with an insulating layer on the inside to avoid short-circuiting (Figure 7). It can also be done by soldering vertical metal strips on the PCB to create compartments. These compartments are closed by adding a lid of flexible die-cut shielding foil (Figure 8) or by pressing a soft foam sheet with a conductive surface against the strips (Figure 9). With the latter option, many compartments can be shielded with just one single cover.

Figure 7. Die-cut shielding box
Figure 7. Die-cut shielding box

Figure 8. PCB shielding
Figure 8. PCB shielding

Figure 9. PCB compartmentalisation
Figure 9. PCB compartmentalisation



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Clearing the Static: Cleaning in an ESD-protected area
Actum Electronics Circuit & System Protection
Cleaning in a protected electrostatic discharge area is a critical task to maintain the integrity of sensitive electronic components and prevent damage caused by static electricity.

Read more...
Clearing the Static: Key principles of ESD control in electronics manufacturing
Actum Electronics Circuit & System Protection
Effectively managing electrostatic discharge is essential in electronics manufacturing to ensure not only product reliability, but also worker safety.

Read more...
Clearing the Static: Three steps for a dry ESD packaging system
Actum Electronics Circuit & System Protection
For optimal storage, it’s essential to complete the dry-packaging system by adding Desiccant Packs and Humidity Indicator Cards.

Read more...
Ensuring safety with earth leakage protection
NewElec Pretoria Circuit & System Protection
Earth leakage protection helps mitigate the risks of electric shocks, fires, and equipment damage by swiftly identifying faults and disconnecting the power supply, thus safeguarding both human lives and machinery.

Read more...
Suppressing EMI with filters
Vepac Electronics Circuit & System Protection
EMI/RFI filters play an important role in reducing the high-frequency noise that is generated by various electrical and electronic devices.

Read more...
Patch attenuates like a shielding cabinet
Würth Elektronik eiSos Circuit & System Protection
Würth Elektronik has launched its hybrid WE-EMIP EMI absorber sheet, a convenient solution for reducing electromagnetic interference by up to 40 dB.

Read more...
Popular aluminium enclosure series expanded
Sivan Electronic Supplies Enclosures, Racks, Cabinets & Panel Products
Gainta has expanded its popular G1xx series of sealed aluminium enclosures which have an IP65 rating to provide protection against dust and moisture.

Read more...
Clearing the Static: Ionisation equipment
Actum Electronics Circuit & System Protection
Electrostatic discharge (ESD) ionisation equipment is designed to neutralise static charges that accumulate on surfaces in environments where ESD-sensitive components or materials are handled. These ...

Read more...
Motor and feeder protection for LV and MV environments
NewElec Pretoria Circuit & System Protection
This relay from NewElec is a micro-controller-based precision instrument with ANSI protection elements, advanced control features, and switchgear controller logic integrating motor and feeder control functions.

Read more...
Clearing the Static: How to protect PCBs from electrostatic discharge and moisture
Actum Electronics Circuit & System Protection
Printed circuit boards (PCBs) are essential components in most electronic devices. They are sensitive to environmental factors like electrostatic discharge (ESD) and moisture, which can cause significant ...

Read more...